The ICU watch board: every finding carries its own follow-through.

Five synthetic patients, one unit. When AI MedAgent finds something, it does not just say it. It sends it to a named role, sets how urgent it is and says why, reminds if nobody answers, escalates to the next person, and writes down every step. That object is the mediator. Watch it work, then answer as the nurse, the pharmacist or the doctor would.

How to use this page

Synthetic patients and a simulated pump feed. Nothing is stored on a server; reset the page and it is gone. Not a medical device. Not for clinical use.

Unit time (simulated)Mon 07:00
Open items: 0 · responded 0 · deferred 0 · rejected 0 · escalations 0

Beds

Open watch items, most urgent first

The watch is reading. Findings appear here as the clock runs.
Closed items
Click a finding or a bed to see the detail.

Unit audit trail

Every step of every mediator, in order. Each line is an AuditEvent in the detail view.

How the mediator maps to published standards

Nothing here is a private format. The finding, the work and the trail are standard HL7 FHIR R4 resources; device-originated alerts have a published IHE path of their own.

Mediator stepFHIR R4 (what this page emits)IHE ACM, for device-originated alerts
The findingDetectedIssue: code, severity, detail, evidenceReport Alert [PCD-04]
Who should hear it, and how urgentTask.owner (a PractitionerRole), Task.priority, CommunicationRequest.recipient and payloadDisseminate Alert [PCD-06]
Reminder and escalation timersTask.restriction.period.end; the chain and minutes in Task.inputSet by the alert manager; delivery status returns in Report Dissemination Alert Status [PCD-07]
Respond, defer, rejectTask.status: completed, on-hold, rejected; Task.statusReason; Task.noteThe recipient's answer returns in [PCD-07]; the alert's status goes back to the reporting device in Report Alert Status [PCD-05]
The trailAuditEvent, one per stepLogged by the alert manager and communicator

Sources: HL7 FHIR R4 (4.0.1) resource definitions for DetectedIssue, Task, CommunicationRequest and AuditEvent. IHE Devices Technical Framework Rev 10.0, Final Text, 4 November 2024, Alert Communication Management (ACM), transactions PCD-04 to PCD-07. The timers shown are demonstration settings; a hospital sets its own. The project's own code system (https://aimedagent.net/fhir/CodeSystem/watch-event) names the audit steps, because no published code fits "escalated after no answer".

Daniel Pettus spent forty years in medical device and health IT leadership at Alaris, CareFusion and BD, contributed to IHE Patient Care Device interoperability standards, and is named on two United States patents. He writes Inside the Loop at insidetheloopdp.substack.com and is the author of The Technology Was Never the Problem, at pettusbook.com.

AI MedAgent is a research demonstration of a patent-pending method. Advisory only. Not a medical device. Not for clinical use. Synthetic data only.